Carousel Work-Up Station

Easy-to-use, 12 position, parallel work-up station reduces post-synthesis bottlenecks. The Carousel Work-Up Station facilitates parallel or sequential work-up of up to 12 samples, using filtration, phase separation, liquid/liquid extraction or SPE techniques.

Carousel Work-Up Station

  • Accepts 12 x 70  ml columns loaded into one of two identical stackable racks
  • The lower rack supports 12 Carousel Reaction Tubes or standard 1 inch boiling tubes for sample collection and the upper rack holds your columns
  • Unique vacuum-free design uses no taps, valves or drip needles, making assembly and operation fast and simple. Minimising cleaning and consumable costs
  • Vacuum-free operation also makes removal of collection tubes easy and prevents drying of columns
Carousel Work Up station

  • Use under gravity or with the SpeediFlow Booster, which allows precise individual control of solvent flow within each column and speeds up your work-ups
  • Ergonomically designed aluminium racks are easy to load with collection tubes or columns. They are stable with good access/visibility of all columns and tubes
  • Identical racks lock together for ease of operation or transportation from location to location
  • An optional 3rd rack can be stacked above the 2nd rack for sequential work-up
Carousel Work Up Station
Carousel Work-Up Station
Carousel Work-Up Station
Carousel Work Up Station

Lightweight aluminium racks

  • Ergonomically designed, lightweight aluminium racks are easy to load with collection tubes or work-up columns

Adding a second rack

  • To locate a second rack on top of the first, pull out the spring loaded knob and rotate 90º

Identical racks lock

  • Identical racks lock together for ease of operation or transportation from location to location

Optional 3rd rack

  • An optional 3rd rack can be stacked above the 2nd rack for sequential work-up

SpeediFlow Booster

  • Use under gravity or with the SpeediFlow Booster, which allows pressurisation or individual columns to increase flow rates and speed up your work-ups

Accepts 12 x Carousel Reaction Tubes

  • Accepts 12 x Carousel Reaction Tubes or standard 1 inch boiling tubes

Optional removable adapters

  • Optional removable adapters are available for use with 15 ml, 25 ml, 70 ml and 150 ml columns plus the Whatman AutoCup®

Vacuum-free operation

  • Vacuum-free operation makes removal of collection tubes easy, prevents drying of columns and reduces the risk of bumping

Carousel Work-Up Station

RR99830   Carousel Work-Up Station (Two racks and SpeediFlow)

Carousel Work-Up Components and Accessories

RR99831   Carousel Work-Up Rack
RR99840   SpeediFlow Gas Connection Tubing – 5m length
RR91080   Quick-Thread Glass Reaction Tube 24mm x 150mm
RR91081   Quick-Thread Glass Reaction Tube 24mm x 150mm

Carousel Work-Up Systems

RR99880 System 25 – Carousel Work-Up Station

Comprising of:
RR99830 – 1 x Carousel Work-Up Station (Two racks and SpeediFlow)
RR99874 – 50 x 20µm PE Filtration 70ml
RR99875 – 50 x Phase Separation 70ml
RR91081 – 12 x Quick-Thread Glass Reaction Tube 24mm x 150mm
RR99840 – 5m length SpeediFlow Gas Connection Tubing

RR99881 System 26 – Carousel Work-Up Station

Comprising of:
RR99830 – 1 x Carousel Work-Up Station (Two racks and SpeediFlow)
RR99831 – 1 x Carousel Work-Up Rack
RR99870 – 16 x Silica 10g/70ml
RR99874 – 50 x 20µm PE Filtration 70ml
RR99875 – 50 x Phase Separation 70ml
RR91081 – 12 x Quick-Thread Glass Reaction Tube 24mm x 150mm
RR99840 – 5m length SpeediFlow Gas Connection Tubing

SpeediFlow™ Adapter Heads

RR99850   SpeediFlow Booster (with 70ml Column Adapter)
RR99852   SpeediFlow Adapter Head (for 15ml Columns)
RR99856   SpeediFlow Adapter Head (for 150ml Columns)
RR99858   SpeediFlow Adapter Head (for Whatman AutoCup®)
RR99862   Replacement Viton O-ring (for 15ml Columns)
RR99864   Replacement Viton O-ring (for 25ml Columns)
RR99860   Replacement Viton O-ring (for 70ml Columns)
RR99861   Replacement Perlast O-ring (for 70ml Columns)
RR99866   Replacement Viton O-ring (for 150ml Columns)
RR99868   Replacement Viton O-ring (for Whatman AutoCup®)

Carousel Work-Up Columns

RR99870   Silica 10g/70ml
RR99871   Aminopropyl 10g/70ml
RR99872   SCX 10g/70ml
RR99873   SAX Acetate 10g/70ml
RR99874   20µm PE Filtration 70ml
RR99875   Phase Separation 70ml
RR99877   Liquid/Liquid Extraction 10ml Sample
RR99878   Liquid/Liquid Extraction 20ml Sample

RR99876   Carousel Work-Up Column Pack
  Comprising of:
RR99870 – 16 x Silica 10g/70ml
RR99871 – 16 x Aminopropyl 10g/70ml
RR99872 – 16 x SCX 10g/70ml
RR99873 – 16 x SAX Acetate 10g/70ml
RR99874 – 50 x 20µm PE Filtration 70ml
RR99875 – 50 x Phase Separation 70ml

SpeediFlow Booster

SpeediFlow™ Booster

  • The SpeediFlow is a hand held pressuriser which fits into the top of your plastic column, to push the mobile phase through the column
  • Features a mechanically expandable Viton O-ring, operated by a trigger with an integral locking device, for unsupported gas tight operation
  • SpeediFlow features a safety relief valve that vents at 6 to 8 psi, preventing accidental over-pressure
  • SpeediFlow Booster increases flow rates to speed up your work-ups
SpeediFlow™ Adapter Heads

SpeediFlow™ Adapter Heads

The SpeediFlow includes a range of optional adapters to fit all standard plastic column sizes including 15 ml, 25 ml, 70 ml and 150 ml, plus the Whatman AutoCup®. Thus allowing the SpeediFlow to be used in other SPE or filtration applications.

Carousel Work-up Station

Changing the adapter head

The removal of adapters is simple. Pull out the locking pin, release the handle and the adapter can be easily pulled out.

Work-Up column packs

Carousel Work-Up Columns

70 ml columns:

  • 20 µm Filtration
  • Phase Separation
  • Silica
  • SCX
  • Aminopropyl
  • SAX Acetate
Introducing Parallel Chemistry Tools - On Demand

Webinar: Introducing - Productivity and Parallel Chemistry tools

An introduction to the range of productivity and parallel chemistry tools in the Radleys range with a live demonstration and hands on approach.

Watch webinar on demand
Humble hotplate webinar - On Demand

Webinar: Unleash your humble hotplate – it can do so much more than you think

Are you making the most of your hotplate?

Louisa Quegan and Keren Abecassis share their chemistry lab hacks: showing you a range of tools you might not know about.

From 1 position to 45 on a single hotplate – with working volumes between 0.5 ml and 2.5 L. Lou and Keren discuss their personal experience in the lab using traditional methods vs. this range of tools.

Watch webinar on demand